Application
Weld Plus by ISOKING™ shear stud connector and metal deck welding application diagram
Technical Details
SHEAR CONNECTOR (SD) (ISO 13918) DIMENSION (in mm) | ||||||
d1-0.4 | 10 | 13 | 16 | 19 | 22 | 25 |
d5±0.3 | 19 | 25 | 32 | 32 | 35 | 41 |
d3±0.3 | 13 | 17 | 21 | 23 | 29 | 31 |
h3±0.3 | 7 | 8 | 8 | 10 | 10 | 12 |
h4 | 2.5 | 3 | 4.5 | 6 | 7 | 7 |
L1±1.5 | 40-105 | 40-160 | 40-200 | 40-250 | 60-250 | 60-250 |
Burn Off | 3 | 3 | 5 | 5 | 5 | 6 |
Ferrule | Uf10 | Uf13 | Uf19 | Uf19 | Uf22 | Uf25 |
Material available: SWRCH 18A
Burn off parameter is the shortage length after welding.
WELD PLUS BY ISOKING Shear Stud Test Result (Mechanical Properes) | |||
TEST ITEM | STANDARD | MEASURE VALUE | RESULT |
TENSILE STRENGTH (MPa) | ≥450 | 495-523 | OK |
YIELD STRENGTH (MPa) | ≥350 | 385-454 | OK |
ELONGATION (%) | ≥15 | 20-26 | OK |
REDUCTION AREA | ≥50 | 60% | OK |